Conductor: Plain flexible compacted copper IEC60228 Class 2
Insulation: mica tape plus XLPE compound insulated
Bedding: halogen free FLAMEBAR ® bedding
Sheath: halogen free LSZH sheath
Design and Construction: IEC60092-353
Nominal Voltage Uo/U: 0,6/1 kV Maximum Votage Umax: 1,2 kV
Flame Retardancy: IEC 60332-1 IEC 60332-3 Cat A
Fire Resistancy: IEC 60331 Corrosivity: IEC 60754-1 IEC 60754-2
Smoke Density: IEC 61034-2
Toxicity and Smoke Density: IMO RESOLUTION MSC 41(64) and ATS 1000.001 tech. spec.
Cold bend and impact test (-40oC) CSA C22.2 No 38-95
Cores Identification: 1 core black, 2 core black & light blue, 3 core black, brown & light blue, 4 core black, blue, brown & white, 5 core white and numbered. Earthing core (on request) green/yellow
Sheath Colour: Black Ref: XI 331cable
Operating temperature: Maximum 100°C, minimium bending -40°C
Standards:
IEC60092-353: power cables for electrical installation in ships
Type approvals: ABS, Bureau Veritas, DNV, Lloyd’s Register & Russian Maritime Register of Shipping
All Cable is sold in 100m Lengths